Alto POSEIDON 5 Service Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
4
1)
Options / model variants
POSEIDON 5
2.2 Operating elements See fold-out page at front of these
operating instructions.
1 Handle
2 Hose reel
3 Mains power lead
4 Tank filler for detergent
5 Filling of pump oil and check
of oil level
6 Detergent tank
7 High pressure hose
connection
8 Supply water connection with
water inlet filter
2 Description
2.1 Purpose This high-pressure cleaner has
been designed for professional
use in:
– agriculture
– industry
– transport industry
– automotive cleaning
– municipal facilities
– cleaning trade
– construction industry
– food industry
etc.
Chapter 5 describes the use of
the high-pressure cleaner for
various cleaning jobs.
Always use the cleaner as de-
scribed in these operating in-
structions. Any other use may
damage the cleaner or the sur-
face to be cleaned or may result
in severe injury to persons.
9 Pressure gauge
10 Detergent metering knob
11 Main switch
12 Pressure regulation on spray
lance
13 Spray lance
14 Receptacle for Spray lance
15 Spray gun
16 Detergent intake hose
17 Receptacle for electrical lead
Nilfisk-Alto dealers in accord-
ance with the maintenace plan.
Failure to do so will invalidate
the warranty.
CAUTION!
High-pressure hoses, fittings
and couplings are important for
the safety of the cleaner. Use
only high-pressure parts ap-
proved by the manufacturer!
The mains power lead must not
differ from the version specified
by the manufacturer and may
only be changed by an electri-
cian.
Please contact the Nilfisk-Alto
service department or an au-
thorised specialist work-shop for
all other maintenance or repair
work!
Testing
The cleaner conforms to the
German „Guidelines for Liq-
uid Spray Jet Devices“. The
high-pressure cleaner must be
subjected to a safety examina-
tion in accordance with the „Ac-
cident Prevention Regulations
for Working with Liquid Spray
Jet Devices“ as required, but at
least every 12 months, by an au-
thorised inspector.
After all repairs or modifica-
tions to electrical equipment,
the protective conductor resist-
ance, the insulation resistance
and the leakage current must
be measured. Furthermore, a
visual inspection of the mains
power lead, a voltage and cur-
rent measurement and a func-
tion test must be carried out.
Our after-sales service techni-
cians are at your disposal as au-
thorised inspectors.
The complete „Accident Preven-
tion Regulations for Working
with Liquid Spray Jet Devices“
are available from the Carl Hey-
manns Verlag KG, Luxemburger
Strasse 449, 50939 Cologne or
from the appropriate associa-
tion of employers’ liability insur-
ances.
Unloader valve
Unacceptably high pressure is
fed back without residual pres-
sure via a bypass line into the
intake line of the pump when the
safety device is tripped.
The unloader valve is set and
sealed at the factory and must
not be adjusted.
Page view 5
1 2 3 4 5 6 7 8 9 10 11 ... 18 19

Comments to this Manuals

No comments