Getting Started Guide 103
Set Up High Availability Verify Failover
Verify Failover
To test that your HA configuration works properly trigger a manual failover and verify that the devices transition
states successfully.
Verify Failover
Step 1 Suspend the active device. Click the Suspend local device link on the Device > High
Availability > Operational Commands
tab.
Step 2 Verify that the passive device has taken
over as active.
On the
Dashboard, verify that the state of the passive device changes
to
active in the High Availability widget.
Step 3 Restore the suspended device to a
functional state. Wait for a couple
minutes, and then verify that preemption
has occurred, if preemptive is enabled.
1. On the device you previously suspended, select the
Make local
device functional
link on the Device > High Availability >
Operational Commands
tab.
2. In the
High Availability widget on the Dashboard, confirm that
the device has taken over as the active device and that the peer
is now in a passive state.