102 Getting Started Guide
Define the Failover Conditions Set Up High Availability
Define the Failover Conditions
Configure the Failover Triggers
Step 1 To configure link monitoring, define the
interfaces that you would like to monitor.
A change in the link state of these
interface will trigger a failover.
1. Select
Device > High Availability > Link and Path Monitoring.
2. In the Link Group section, click Add.
3. Name the Link Group, Add the interfaces to monitor, and select
the
Failure Condition for the group. The Link group you define
is added to the
Link Group section.
Step 2 (Optional) Modify the failure condition
for the Link Groups that you configured
(in the preceding step) on the device.
By default, the device will trigger a
failover when any monitored link fails.
1. Select the
Link Monitoring section.
2. Set the Failure Condition to All.
The default setting is Any.
Step 3 To configure path monitoring, define the
destination IP addresses that the firewall
should ping to verify network
connectivity.
1. In the
Path Group section of the Device > High Availability >
Link and Path Monitoring
tab, pick the option for your setup:
Add Virtual Wire Path, Add VLAN Path, Add Virtual Router
Path
.
2. Select the appropriate item from the drop-down list for the
Name and Add the IP addresses (source and/or destination, as
prompted) that you wish to monitor. Then select the
Failure
Condition
for the group. The path group you define is added to
the
Path Group section.
Step 4 (Optional) Modify the failure condition
for all Path Groups configured on the
device.
By default, the device will trigger a
failover when any monitored path fails.
Set the
Failure Condition to All.
The default setting is Any.
Step 5 Save your changes.
Click Commit.